Example snow guard systems with S‑5!®
S‑5!® ColorGard® – the snow guard in the color of the metal roof












Round tube snow guard with the RoofTech single-tube and double-tube holders















Please note:
The decision on whether to install a snow guard system depends on the use and location of the building and ultimately always lies with the builder or homeowner. If there are official regulations, these must be taken into account. The snow guard system is designed to prevent the shearing effect of the snow lying on the roof across the entire area by means of one or more rows of snow guards. In Germany, the design and dimensioning of the snow guard system must be carried out in advance by a professional in accordance with DIN EN 1991-Eurocode 1–3: “Actions on structures – Snow loads” (in Austria according to ÖNORM B 1991–1‑3:2006–04-01, in Switzerland SIA 261:2003 applies). They are valid up to altitudes of 1500 m. Altitudes above this are regulated by special national regulations.
RoofTech and S‑5! recommend that the planned installation and the design of the snow guard be reviewed by a qualified professional who is responsible for the correct application of the relevant building codes, standards, technical rules and local factors, snow and wind loads, the loads of the installation, the statics and assembly as well as the planning and construction of and on metal roofs.
With very few exceptions, the load-bearing capacity of each individual S‑5!® clamp is greater than the load-bearing capacity of the roof panels or profile sheets and their fastening to the supporting structure. This applies not only to the normal clamps but also to the S‑5!® mini clamps. Therefore, the weak points are usually not the clamps, but the roof covering and its fastening.
Depending on the use of the respective S‑5!® clamp, it must be ensured that the forces transferred from the clamp to the seam can be absorbed by the seam or by the supporting structure. In particular, the snow and wind loads, the additional loads from the installations attached to the clamps, as well as the increased stresses in the edge and corner areas of the roof structure must be taken into account. A sufficient number of clamps must be provided. For statically relevant clamps, a distance of at least 500 mm from the end of the standing seam profile must be maintained.
Please always follow the installation instructions for the respective S‑5!® clamps and the other products used! The respective installation instructions do not release the executing company from the obligation to clarify the possible uses and application of our products, also in connection with the other materials used, on the individual object in advance. RoofTech, S‑5!® and the other producers generally do not accept any responsibility for suitability, processing and correct use. If our installation instructions are not followed and if other components are used that were not purchased from us, we accept no liability for any resulting defects or damage. The warranty is therefore excluded.
The drawings and photos shown in our documents and on our and the S‑5! homepage serve to clarify individual details and are merely recommendations. RoofTech and S‑5! assume no further liability.
RoofTech GmbH, S‑5!® – Metal Roof Innvovations Ltd. and the other producers generally do not accept responsibility for installation and application.
Our documents and the individual assembly instructions for our products can be downloaded on the respective page and above under DownloadsWe would be happy to send you the information you require. We look forward to your message or call.
No liability for printing and typing errors. Technical changes reserved. We accept no liability for errors on our homepage and in our documents. Descriptions, images and drawings may represent stages of development that are not available in this form.
The contents of the RoofTech website and our documents (text, images, logos, drawings, trademarks and other data) are protected by copyright. The contents of this website and our documents may not be copied, distributed, modified or made available to third parties for commercial purposes. Any content on our homepage and our documents may only be used or passed on with the agreement and consent of RoofTech GmbH!
S‑5!® products are protected by international patents of Metal Roof Innovations Ltd. For the use of all data and documents from S‑5! Metal Roof Innovations Ltd. please observe the S‑5! Terms of Use (=> direct link to S‑5! Terms of Use). Please also note the protective rights and copyright notices of our other producers and suppliers.
Linking external websites to the RoofTech website is only permitted with the consent of RoofTech GmbH and if no rights of RoofTech GmbH are violated.
The business relationship is subject to German law, excluding the UN Convention on Contracts for the International Sale of Goods (CISG). Our General Terms and Conditions (GTC) apply, which we are happy to make available to you at any time (=> direct link to the general terms and conditions of RoofTech GmbH).
Sales are generally only made to entrepreneurs (§ 14 BGB – commercial users).
© Copyright RoofTech GmbH, 2025. All rights reserved.